You in into setup mode pressing the middle button while 3 seconds.
Se ingresa en el modo configuración presionando el botón central. The screen will show: SET-XX where XX is the version of product.
Use upper an lower buttons to choose the apropriated option and press the central button. Change the values with the Upper and Lower buttons. At end use the middle button again.
Cr1
Critical Temperature
Choose the temperature taking care that the advice start whe this number is override. An the shutdown is 6 degrees more than this number
Cr2
Temperature
Choose the temperature taking care that the advice start whe this number is override. An the shutdown is 6 degrees more than this number
VMI
Voltage Mínimum
Choose the thereshold voltage under that trigger the alarm
VMA
Voltage Máximum
Choose the thereshold voltage over that trigger the alarm
FAN
Electro
0=with the fan off there are 12v
1=with the fan off there are 0V in the wire
C-F
Grados
0=Centigrades degrees
1=Fahrenheit degrees
BrI
Brightness
Adjusts the screen brightness
DLY
Delay
Isthe time in seconds between the shutdown condition and the shutdown
DRV
Driver
1= Forces the driver to wait for the engine to cool down before being able to continue driving. (It is recommended to activate a delay that allows the driver to park to the side)
GPS
GPS
(only in models with this signal) Select wich temperature will be send to the GPS tracking system
EnD
END
Store the changes and end the setup menu.